Fluidlexikon

Accumulator consumption diagram

In the case of the accumulator supplies the size of the hydraulic accumulator is determined using the pressure oil requirements of all consumers dependent on the accumulator during a working cycle and is determined by the size of the flow rate of the pump (= usable volume V N).

To assess the flow requirements per working cycle, it is practical to create an accumulator consumption diagram (Figure S 69). The pump must be selected with a certain size in order to replace the removed usable volume before the end of the working cycle:

speicherverbrauchsdiagramm_01.gif

The factor k (approx. 1.25) serves to relieve the burden on the pump during part of the working cycle.

0001_speicherverbrauchsdiagramm

Figure S 69: Accumulator consumption diagram