Fluidlexikon

Contamination class

The particle size of the contamination in a hydraulic fluid is spread over a wide area.

In view of this fact, contamination classes have been created that set out the contamination in SAE-ASTM-AIA and NAS 1638 in five size ranges and the particle distribution that is still permissible in ISO 4406 in three ranges for >4, >6 and >14 μm.

These contamination classes also form the basis for the determination of the degree of purity of the hydraulic fluid after the filter.

0001_verschmutzungsklasse.gif

Table V 1: Contamination classes according to NAS 1638

0002_verschmutzungsklasse.gif

Figure V 18: Contamination classes in accordance with ISO 4406

0003_verschmutzungsklasse.gif

Table V 2: Allocation of contamination classes to areas of application